| Assessment Year | 2026 |
|---|---|
| Principal Product | Insulation |
| NAICS | 326150: Urethane and Other Foam Product (except Polystyrene) Manufacturing |
| SIC | 3086: Plastics Foam Products |
| Sales Range | $100 M to 500M |
| # of Employees | 78 |
| Plant Area |
235,000
ft2
|
| Annual Production | 227,800,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $168,802 | 2,648,925 |
kWh
|
$0.064 |
| Electricity Demand | $126,463 | 6,494 |
kW-mo/yr
|
$19.47 |
| Natural Gas | $247,369 | 37,456 |
MMBtu
|
$6.60 |
| TOTAL YEARLY COSTS | $542,634 | |||
| RECOMMENDED SAVINGS* | $45,634 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7243: Improve air circulation with destratification fans / other methods | $13,322 | $60,000 |
$(-2,315.5)
(-36,181)
kWh
|
$(-80.4)
-
kW-mo/yr
|
$15,718
-
MMBtu
|
|
| 02 | 2.2136: Install / repair insulation on steam lines | $6,802 | $7,800 | - | - |
$6,802
-
MMBtu
|
|
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,617 | $650 |
$(-15.4)
(-240)
kWh
|
- |
$3,632
-
MMBtu
|
|
| 04 | 2.4323: Use optimum size and capacity equipment | $7,039 | $10,767 |
$4,158
64,966
kWh
|
$2,881
-
kW-mo/yr
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $4,736 | $15,660 |
$1,722
26,900
kWh
|
$3,015
-
kW-mo/yr
|
- | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,443 | $1,485 |
$3,117
48,708
kWh
|
$1,326
-
kW-mo/yr
|
- | |
| 07 | 2.4221: Install compressor air intakes in coolest locations | $2,256 | $3,000 |
$1,582
24,727
kWh
|
$674
-
kW-mo/yr
|
- | |
| 08 | 2.2625: Chill water to the highest temperature possible | $3,418 | $2,926 |
$2,157
33,696
kWh
|
$1,262
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $45,634 | $102,288 |
$10,404
162,576
kWh
|
$9,077
-
kW-mo/yr
|
$26,152
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs