Assessment Year | 2025 |
---|---|
Principal Product | Sweet corn seeds, beans |
NAICS | 311423: Dried and Dehydrated Food Manufacturing |
SIC | 2034: Dried and Dehydrated Fruits, Vegetables, and Soup Mixes |
Sales Range | $10 M to 50M |
# of Employees | 50 |
Plant Area |
130,000
ft2
|
Annual Production | 8,200
ton
|
Production Hrs. Annual | 3,800
hrs
|
Location (State) | Idaho |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $67,437 | 1,318,710 |
kWh
|
$0.051 |
Electricity Demand | $67,496 | 7,342 |
kW-mo/yr
|
$9.19 |
Electricity Fees | $17,663 | - |
|
- |
Natural Gas | $75,780 | 13,370 |
MMBtu
|
$5.67 |
LPG | $17,030 | 963 |
MMBtu
|
$17.68 |
Other Gas | $41,030 | 1,340 |
MMBtu
|
$30.62 |
TOTAL YEARLY COSTS | $286,436 | |||
RECOMMENDED SAVINGS* | $77,414 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Gas Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $31,860 | $229,735 |
$15,310
299,390
kWh
|
$16,550
-
kW-mo/yr
|
- | - | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $1,860 | $400 |
$790
15,500
kWh
|
$1,070
-
kW-mo/yr
|
- | - | - | |
03 | 2.4323: Use optimum size and capacity equipment | $1,950 | $24,760 |
$1,950
38,000
kWh
|
- | - | - | - | |
04 | 2.4225: Install common header on compressors | $23,050 | $394,000 |
$(-10,960.0)
(-214,100)
kWh
|
$(-7,020.0)
-
kW-mo/yr
|
- | - |
$41,030
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,700 | $2,950 |
$1,700
33,000
kWh
|
- | - | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $2,160 | $1,440 |
$2,160
42,200
kWh
|
- | - | - | - | |
07 | 2.5123: Reduce fluid flow rates | $2,210 | $30,850 |
$1,320
25,500
kWh
|
$890
-
kW-mo/yr
|
- | - | - | |
08 | 4.821: Pay bills on time to avoid late fees | $694 | $720 | - | - | $624 |
$70
-
MMBtu
|
- | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,110 | $41,570 |
$7,090
138,610
kWh
|
$1,020
-
kW-mo/yr
|
- | - | - | |
10 | 2.7135: Install occupancy sensors | $3,820 | $17,670 |
$3,200
62,750
kWh
|
$620
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $77,414 | $744,095 |
$22,560
440,850
kWh
|
$13,130
-
kW-mo/yr
|
$624 |
$70
-
MMBtu
|
$41,030
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Other Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs