Assessment Year | 1999 |
---|---|
Principal Product | Cardboard Boxes |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 140 |
Plant Area |
227,000
ft2
|
Annual Production | 1,000,000,000
thousand feet
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Florida |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $287,893 | 12,854,924 |
kWh
|
$0.022 |
Electricity Demand | $52,117 | 27,750 |
kW-mo/yr
|
$1.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $84,683 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $55,934 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,105 | $1,000 |
$2,105
117,819
kWh
|
- | - | - | - | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,042 | $2,836 |
$1,042
30,188
kWh
|
- | - | - | - | - | |
03 | 2.3212: Optimize plant power factor | $2,089 | - | - | $2,089 | - | - | - | - | |
04 | 2.1213: Direct warmest air to combustion intake | $16,001 | $16,000 | - | - |
$16,001
-
MMBtu
|
- | - | - | |
05 | 3.4155: Meter waste water | $6,128 | $1,500 | - | - | - |
$6,128
-
Tgal
|
- | - | |
06 | 4.711: Initiate a total quality management program | $50,698 | $22,390 | - | - | - | - |
$50,698
-
lb
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $6,620 | $2,990 | - | - | - | - | - | $6,620 | |
TOTAL RECOMMENDED | $84,683 | $46,716 |
$3,147
148,007
kWh
|
$2,089 |
$16,001
-
MMBtu
|
$6,128
-
Tgal
|
$50,698
-
lb
|
$6,620 | ||
TOTAL IMPLEMENTED | $55,934 | $26,226 |
$3,147
148,007
kWh
|
$2,089 | - | - |
$50,698
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs