ITAC Assessment: UU0191
ITAC logo
ITAC Assessment: UU0191
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Treated Wastewater
NAICS 237110: Water and Sewer Line and Related Structures Construction
SIC 1623: Water, Sewer, Pipeline, and Communications and Power Line Construction
Sales Range $1
M
to 5
M
# of Employees 6
Plant Area 71,000
ft2
Annual Production 803,534
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $142,659 3,973,798
kWh
Electricity Demand $142,659 8,784
kW-mo/yr
Natural Gas $20,198 2,889
MMBtu
TOTAL YEARLY COSTS $305,517
RECOMMENDED SAVINGS* $39,972 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $32,769

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.4322: Use or replace with energy efficient substitutes $19,749 $38,000 $12,193
339,645
kWh
$7,556
-
kW-mo/yr
- -
02 2.8113: Purchase gas directly from a contract gas supplier $7,428 $14,400 - - $7,428 -
03 2.9113: Use solar heat for heat $4,877 $10,800 - - - $4,877
-
MMBtu
04 2.7221: Lower temperature during the winter season and vice-versa $3,303 $150 - - - $3,303
-
MMBtu
05 2.7142: Utilize higher efficiency lamps and/or ballasts $2,175 $4,613 $1,154
32,132
kWh
$1,021
-
kW-mo/yr
- -
06 2.4221: Install compressor air intakes in coolest locations $2,172 $2,482 $1,341
37,354
kWh
$831
-
kW-mo/yr
- -
07 2.6218: Turn off equipment when not in use $154 $71 $154
4,287
kWh
- - -
08 2.7221: Lower temperature during the winter season and vice-versa $114 $50 $114
3,174
kWh
- - -
TOTAL RECOMMENDED $39,972 $70,566 $14,955
416,592
kWh
$9,408
-
kW-mo/yr
$7,428 $8,180
-
MMBtu
TOTAL IMPLEMENTED $32,769 $57,213 $13,461
374,951
kWh
$8,577
-
kW-mo/yr
$7,428 $3,303
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs