Assessment Year 2019
Principal Product Auto parts
NAICS 336390: Other Motor Vehicle Parts Manufacturing
SIC 3714: Motor Vehicle Parts and Accessories
Sales Range $10
M
to 50
M
# of Employees 147
Plant Area 211,035
ft2
Annual Production 730
units
Production Hrs. Annual 2,086
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $43,628 869,149
kWh
Electricity Demand $49,524 3,632
kW-mo/yr
Electricity Fees $4,091 -
Natural Gas $63,500 8,469
MMBtu
Waste Disposal Costs
Water Usage $40,964 18,258
Tgal
TOTAL YEARLY COSTS $201,708
RECOMMENDED SAVINGS* $45,274 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $45,274

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $15,321 $68,567 $5,763
158,188
kWh
$9,558
-
kW-mo/yr
- -
02 2.3212: Optimize plant power factor $2,079 $4,000 - $2,079
-
kW-mo/yr
- -
03 2.7231: Use radiant heater for spot heating $12,670 $22,920 - - - $12,670
-
MMBtu
04 2.4226: Use / purchase optimum sized compressor $9,094 $8,488 $5,626
156,278
kWh
$3,468
-
kW-mo/yr
- -
05 2.6218: Turn off equipment when not in use $314 $218 $314
8,599
kWh
- - -
06 2.7243: Improve air circulation with destratification fans / other methods $3,916 $3,800 $3,524
32,036
kWh
$392
-
kW-mo/yr
- -
07 2.8121: Apply for tax-free status for energy purchases $1,880 $650 - - $1,880 -
TOTAL RECOMMENDED $45,274 $108,643 $15,227
355,101
kWh
$15,497
-
kW-mo/yr
$1,880 $12,670
-
MMBtu
TOTAL IMPLEMENTED $45,274 $108,643 $15,227
355,101
kWh
$15,497
-
kW-mo/yr
$1,880 $12,670
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs