Assessment Year | 2019 |
---|---|
Principal Product | Auto parts |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 147 |
Plant Area |
211,035
ft2
|
Annual Production | 730
units
|
Production Hrs. Annual | 2,086
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $43,628 | 869,149 |
kWh
|
$0.050 | |
Electricity Demand | $49,524 | 3,632 |
kW-mo/yr
|
$13.64 | |
Electricity Fees | $4,091 | - |
|
- | |
Natural Gas | $63,500 | 8,469 |
MMBtu
|
$7.50 | |
Waste Disposal Costs | |||||
Water Usage | $40,964 | 18,258 |
Tgal
|
$2.24 | |
TOTAL YEARLY COSTS | $201,708 | ||||
RECOMMENDED SAVINGS* | $45,274 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $45,274 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,321 | $68,567 |
$5,763
158,188
kWh
|
$9,558
-
kW-mo/yr
|
- | - | |
02 | 2.3212: Optimize plant power factor | $2,079 | $4,000 | - |
$2,079
-
kW-mo/yr
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $12,670 | $22,920 | - | - | - |
$12,670
-
MMBtu
|
|
04 | 2.4226: Use / purchase optimum sized compressor | $9,094 | $8,488 |
$5,626
156,278
kWh
|
$3,468
-
kW-mo/yr
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $314 | $218 |
$314
8,599
kWh
|
- | - | - | |
06 | 2.7243: Improve air circulation with destratification fans / other methods | $3,916 | $3,800 |
$3,524
32,036
kWh
|
$392
-
kW-mo/yr
|
- | - | |
07 | 2.8121: Apply for tax-free status for energy purchases | $1,880 | $650 | - | - | $1,880 | - | |
TOTAL RECOMMENDED | $45,274 | $108,643 |
$15,227
355,101
kWh
|
$15,497
-
kW-mo/yr
|
$1,880 |
$12,670
-
MMBtu
|
||
TOTAL IMPLEMENTED | $45,274 | $108,643 |
$15,227
355,101
kWh
|
$15,497
-
kW-mo/yr
|
$1,880 |
$12,670
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs