Assessment Year 2019
Principal Product bulk powder capsules
NAICS 325411: Medicinal and Botanical Manufacturing
SIC 2833: Medicinal Chemicals and Botanical Products
Sales Range $50
M
to 100
M
# of Employees 70
Plant Area 48,000
ft2
Annual Production 300,000,000
units
Production Hrs. Annual 4,030
hrs
Location (State) Utah

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $36,661 1,002,480
kWh
Electricity Demand $47,777 2,861
kW-mo/yr
Electricity Fees $7,951 -
Natural Gas $9,862 1,224
MMBtu
TOTAL YEARLY COSTS $102,251
RECOMMENDED SAVINGS* $20,411 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $5,874 $9,432 $1,758
48,051
kWh
$4,116
-
kW-mo/yr
- -
02 2.8121: Apply for tax-free status for energy purchases $5,611 $1,000 - - $5,611 -
03 2.4231: Reduce the pressure of compressed air to the minimum required $2,173 $120 $690
18,640
kWh
$1,483
-
kW-mo/yr
- -
04 2.3132: Recharge batteries on during off-peak demand periods $1,980 - - $1,980
-
kW-mo/yr
- -
05 2.7224: Reduce space conditioning during non-working hours $1,945 $200 $859
23,200
kWh
- - $1,086
-
MMBtu
06 2.6231: Utilize controls to operate equipment only when needed $824 $1,208 $507
13,862
kWh
$317
-
kW-mo/yr
- -
07 2.4234: Cool compressor air intake with heat exchanger $797 $1,990 $304
8,300
kWh
$493
-
kW-mo/yr
- -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $495 $286 $210
5,740
kWh
$285
-
kW-mo/yr
- -
09 2.6231: Utilize controls to operate equipment only when needed $391 $300 $391
10,693
kWh
- - -
10 2.7135: Install occupancy sensors $322 $402 $322
8,808
kWh
- - -
TOTAL RECOMMENDED $20,411 $14,938 $5,041
137,294
kWh
$8,673
-
kW-mo/yr
$5,611 $1,086
-
MMBtu
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs