Assessment Year | 2019 |
---|---|
Principal Product | Beer |
NAICS | 312120: Breweries |
SIC | 2082: Malt Beverages |
Sales Range | $5 M to 10M |
# of Employees | 52 |
Plant Area |
27,000
ft2
|
Annual Production | 31,000
units
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $66,840 | 483,449 |
kWh
|
$0.14 | |
Natural Gas | $20,890 | 4,078 |
MMBtu
|
$5.12 | |
Waste Disposal Costs | |||||
Water Usage | $14,329 | 3,148 |
Tgal
|
$4.55 | |
TOTAL YEARLY COSTS | $102,058 | ||||
RECOMMENDED SAVINGS* | $48,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $1,877 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | By-product Production Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.1175: Use a different or recycled raw material | $37,500 | $225,000 | - | - | - | - | - | $37,500 | |
02 | 2.8114: Change rate schedules or other changes in utility service | $2,186 | $2,000 | - | - | - | - |
$2,186
-
Tgal
|
- | |
03 | 2.4235: Remove or close off unneeded compressed air lines | $1,780 | - |
$1,780
12,900
kWh
|
- | - | - | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,035 | $350 |
$1,035
7,500
kWh
|
- | - | - | - | - | |
05 | 2.2136: Install / repair insulation on steam lines | $850 | - | - | - | - |
$850
-
MMBtu
|
- | - | |
06 | 2.6231: Utilize controls to operate equipment only when needed | $693 | $2,575 |
$693
5,020
kWh
|
- | - | - | - | - | |
07 | 2.2491: Use cooling air which cools hot work pieces for space heating | $367 | $1,200 |
$50
362
kWh
|
$317
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7493: Use double or triple glazed windows to maintain higher relative humidity and to reduce heat losses | $231 | $1,100 |
$36
264
kWh
|
- | - |
$195
-
MMBtu
|
- | - | |
09 | 2.2533: Replace air curtain doors with solid doors | $97 | $75 |
$97
702
kWh
|
- | - | - | - | - | |
10 | 2.8121: Apply for tax-free status for energy purchases | $3,482 | $1,000 | - | - | $3,482 | - | - | - | |
TOTAL RECOMMENDED | $48,220 | $233,300 |
$3,691
26,748
kWh
|
$317
-
kW-mo/yr
|
$3,482 |
$1,045
-
MMBtu
|
$2,186
-
Tgal
|
$37,500 | ||
TOTAL IMPLEMENTED | $1,877 | $75 |
$1,877
13,602
kWh
|
- | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | By-product Production Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs