Assessment Year | 2017 |
---|---|
Principal Product | Roofing Material |
NAICS | 326140: Polystyrene Foam Product Manufacturing |
SIC | 3086: Plastics Foam Products |
Sales Range | $1 M to 5M |
# of Employees | 60 |
Plant Area |
500,000
ft2
|
Annual Production | 1,250
thousand feet
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $384,394 | 10,234,800 |
kWh
|
$0.038 |
Electricity Demand | $325,046 | 24,900 |
kW-mo/yr
|
$13.05 |
Electricity Fees | $239,422 | - |
|
- |
Natural Gas | $61,018 | 11,815 |
MMBtu
|
$5.16 |
TOTAL YEARLY COSTS | $1,009,880 | |||
RECOMMENDED SAVINGS* | $297,736 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $69,707 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $204,798 | - | - |
$129,648
-
kW-mo/yr
|
$75,150 | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $55,559 | $500 | - | - | $55,559 | - | |
03 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $15,162 | $26,440 | - | - | - |
$15,162
-
MMBtu
|
|
04 | 2.4224: Upgrade controls on compressors | $7,349 | $800 |
$1,984
52,208
kWh
|
$3,932
-
kW-mo/yr
|
$1,434 | - | |
05 | 2.7135: Install occupancy sensors | $6,799 | $4,244 |
$6,799
178,926
kWh
|
- | - | - | |
06 | 2.2511: Insulate bare equipment | $5,324 | $11,240 |
$(-413.9)
10,893
kWh
|
$(-194.8)
-
kW-mo/yr
|
$(-71.0) |
$6,004
-
MMBtu
|
|
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,745 | - |
$1,054
27,742
kWh
|
$1,239
-
kW-mo/yr
|
$452 | - | |
TOTAL RECOMMENDED | $297,736 | $43,224 |
$9,423
269,769
kWh
|
$134,624
-
kW-mo/yr
|
$132,524 |
$21,165
-
MMBtu
|
||
TOTAL IMPLEMENTED | $69,707 | $5,544 |
$8,783
231,134
kWh
|
$3,932
-
kW-mo/yr
|
$56,993 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs