Assessment Year | 2006 |
---|---|
Principal Product | printed materials |
NAICS | 323113: Commercial Screen Printing |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
30,000
ft2
|
Annual Production | 25,000,000
pieces
|
Production Hrs. Annual | 2,496
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $14,513 | 563,820 |
kWh
|
$0.026 |
Electricity Demand | $28,998 | 2,655 |
kW-mo/yr
|
$10.92 |
Natural Gas | $25,905 | 2,905 |
MMBtu
|
$8.92 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $61,426 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,610 | $1,995 |
$1,760
62,730
kWh
|
$850
-
kW-mo/yr
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $560 | $25 |
$380
13,400
kWh
|
$180
-
kW-mo/yr
|
- | |
03 | 2.4237: Substitute compressed air cooling with water or air cooling | $2,760 | $212 |
$1,860
66,130
kWh
|
$900
-
kW-mo/yr
|
- | |
04 | 2.4156: Establish a preventative maintenance program | $47,500 | $23,700 | - | - | $47,500 | |
05 | 2.3191: Use demand controller or load shedder | $6,510 | $5,000 | - |
$6,510
-
kW-mo/yr
|
- | |
06 | 4.821: Pay bills on time to avoid late fees | $706 | - | - | - | $706 | |
07 | 4.652: Replace existing equipment with more suitable substitutes | $50 | $115 |
$50
1,935
kWh
|
- | - | |
08 | 2.7144: Install spectral reflectors / delamp | $730 | $6,080 |
$730
26,090
kWh
|
- | - | |
TOTAL RECOMMENDED | $61,426 | $37,127 |
$4,780
170,285
kWh
|
$8,440
-
kW-mo/yr
|
$48,206 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs