Assessment Year | 2004 |
---|---|
Principal Product | gears |
NAICS | 333612: Speed Changer, Industrial High-Speed Drive, and Gear Manufacturing |
SIC | 3566: Speed Changers, Industrial High-Speed Drives, and Gears |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
190,000
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 5,564
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $220,173 | 7,914,600 |
kWh
|
$0.028 |
Electricity Demand | $153,570 | 19,817 |
kW-mo/yr
|
$7.75 |
Electricity Fees | $26,095 | - |
|
- |
Natural Gas | $72,301 | 16,512 |
MMBtu
|
$4.38 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $33,193 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $9,695 | $28,050 | - | - | $9,695 | - | - | |
02 | 2.3191: Use demand controller or load shedder | $15,316 | $6,000 | - |
$15,316
-
kW-mo/yr
|
- | - | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $1,810 | $5,100 |
$133
4,641
kWh
|
$1,677
-
kW-mo/yr
|
- | - | - | |
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $212 | $385 |
$285
9,884
kWh
|
$197
-
kW-mo/yr
|
- | - | $(-270.0) | |
05 | 2.4221: Install compressor air intakes in coolest locations | $1,551 | $860 |
$1,106
38,520
kWh
|
$445
-
kW-mo/yr
|
- | - | - | |
06 | 2.7124: Make a practice of turning off lights when not needed | $1,486 | - |
$758
26,411
kWh
|
$728
-
kW-mo/yr
|
- | - | - | |
07 | 2.6218: Turn off equipment when not in use | $3,123 | $360 | - | - | - |
$3,123
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $33,193 | $40,755 |
$2,282
79,456
kWh
|
$18,363
-
kW-mo/yr
|
$9,695 |
$3,123
-
MMBtu
|
$(-270.0) | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs