| Assessment Year | 2002 |
|---|---|
| Principal Product | Sporting Goods |
| NAICS |
n/a
|
| SIC | 3949: Sporting and Athletic Goods, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 312 |
| Plant Area |
110,000
ft2
|
| Annual Production | 50,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $237,336 | 9,038,216 |
kWh
|
$0.026 |
| Electricity Demand | $166,709 | 21,719 |
kW-mo/yr
|
$7.68 |
| Electricity Fees | $49,276 | - |
|
- |
| Natural Gas | $223,906 | 38,990 |
MMBtu
|
$5.74 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $76,526 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $15,793 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $11,006 | $21,657 |
$7,807
259,053
kWh
|
$3,199
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,242 | $2,173 |
$1,601
53,125
kWh
|
$641
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4314: Use synthetic lubricant | $1,257 | $800 |
$897
29,752
kWh
|
$360
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $1,089 | $489 |
$777
25,833
kWh
|
$312
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,441 | $2,664 |
$1,503
49,886
kWh
|
$938
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.2514: Cover open tanks | $739 | $100 | - | - |
$739
-
MMBtu
|
- | - | |
| 07 | 3.8225: Replace hexavalent chromium solutions with trivalent solutions | $716 | - | - | - | - | - |
$716
-
lb
|
|
| 08 | 3.4156: Use flow control valves on equipment to optimize water use | $6,853 | $1,570 | - | - | - |
$6,853
-
Tgal
|
- | |
| 09 | 3.4113: Treat and reuse rinse waters | $50,183 | $98,800 | - | - | - |
$50,183
-
Tgal
|
- | |
| TOTAL RECOMMENDED | $76,526 | $128,253 |
$12,585
417,649
kWh
|
$5,450
-
kW-mo/yr
|
$739
-
MMBtu
|
$57,036
-
Tgal
|
$716
-
lb
|
||
| TOTAL IMPLEMENTED | $15,793 | $25,610 |
$10,984
364,524
kWh
|
$4,809
-
kW-mo/yr
|
- | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs