Assessment Year | 2001 |
---|---|
Principal Product | Trailer Manufacturer |
NAICS |
n/a
|
SIC | 3792: Travel Trailers and Campers |
Sales Range | $10 M to 50M |
# of Employees | 165 |
Plant Area |
15,000
ft2
|
Annual Production | 3,500
pieces
|
Production Hrs. Annual | 4,590
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,626 | 584,493 |
kWh
|
$0.028 |
Electricity Demand | $38,144 | 5,160 |
kW-mo/yr
|
$7.39 |
Electricity Fees | $3,665 | - |
|
- |
Natural Gas | $28,923 | 6,046 |
MMBtu
|
$4.78 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,674 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,525 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,732 | $461 |
$708
23,489
kWh
|
$1,024
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,664 | $215 |
$1,985
65,680
kWh
|
$1,679
-
kW-mo/yr
|
|
03 | 2.4221: Install compressor air intakes in coolest locations | $483 | $462 |
$261
8,635
kWh
|
$222
-
kW-mo/yr
|
|
04 | 2.4314: Use synthetic lubricant | $378 | $300 |
$198
6,571
kWh
|
$180
-
kW-mo/yr
|
|
05 | 2.4133: Use most efficient type of electric motors | $417 | $388 |
$219
7,248
kWh
|
$198
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $6,674 | $1,826 |
$3,371
111,623
kWh
|
$3,303
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $4,525 | $977 |
$2,444
80,886
kWh
|
$2,081
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs