| Assessment Year | 2001 |
|---|---|
| Principal Product | Trailer Manufacturer |
| NAICS |
n/a
|
| SIC | 3792: Travel Trailers and Campers |
| Sales Range | $10 M to 50M |
| # of Employees | 165 |
| Plant Area |
15,000
ft2
|
| Annual Production | 3,500
pieces
|
| Production Hrs. Annual | 4,590
hrs
|
| Location (State) | Utah |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $16,626 | 584,493 |
kWh
|
$0.028 |
| Electricity Demand | $38,144 | 5,160 |
kW-mo/yr
|
$7.39 |
| Electricity Fees | $3,665 | - |
|
- |
| Natural Gas | $28,923 | 6,046 |
MMBtu
|
$4.78 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $6,674 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,525 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,732 | $461 |
$708
23,489
kWh
|
$1,024
-
kW-mo/yr
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,664 | $215 |
$1,985
65,680
kWh
|
$1,679
-
kW-mo/yr
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $483 | $462 |
$261
8,635
kWh
|
$222
-
kW-mo/yr
|
|
| 04 | 2.4314: Use synthetic lubricant | $378 | $300 |
$198
6,571
kWh
|
$180
-
kW-mo/yr
|
|
| 05 | 2.4133: Use most efficient type of electric motors | $417 | $388 |
$219
7,248
kWh
|
$198
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $6,674 | $1,826 |
$3,371
111,623
kWh
|
$3,303
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $4,525 | $977 |
$2,444
80,886
kWh
|
$2,081
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs