ITAC Assessment: LE0552
ITAC logo
ITAC Assessment: LE0552
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2023
Principal Product reamers
NAICS 423830: Industrial Machinery and Equipment Merchant Wholesalers
SIC 5084: Industrial Machinery and Equipment
Sales Range $5
M
to 10
M
# of Employees 125
Plant Area 98,000
ft2
Annual Production 450,000
units
Production Hrs. Annual 7,488
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $90,661 1,421,680
kWh
Electricity Demand $20,179 5,039
kW-mo/yr
Electricity Fees $12,018 -
LPG $31,241 1,382
MMBtu
Fuel Oil #1 $25,319 828
MMBtu
Waste Disposal Costs
Water Usage $16,676 922
Tgal
TOTAL YEARLY COSTS $196,094
RECOMMENDED SAVINGS* $47,359 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $9,403

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings LPG Savings Water Usage Savings Administrative Changes Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $608 $100 $553
8,646
kWh
$55
-
kW-mo/yr
- - -
02 2.7261: Install timers and/or thermostats $790 $570 $239
3,730
kWh
- $551
-
MMBtu
- -
03 2.2443: Re-use or recycle hot or cold process exhaust air $2,712 $2,500 - - $2,712
-
MMBtu
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $231 $320 $193
3,028
kWh
$38
-
kW-mo/yr
- - -
05 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $3,342 $5,052 $3,038
47,481
kWh
$304
-
kW-mo/yr
- - -
06 2.2628: Utilize a less expensive cooling method $12,123 $35,000 $(-4,193.0)
(-65,520)
kWh
$(-360.0)
-
kW-mo/yr
- $16,676
-
Tgal
-
07 2.6212: Turn off equipment during breaks, reduce operating time $448 $2,100 $448
6,989
kWh
- - - -
08 2.7232: Replace existing hvac unit with high efficiency model $1,547 $10,241 $1,407
21,985
kWh
$140
-
kW-mo/yr
- - -
09 2.7233: Use properly designed and sized hvac equipment $5,062 $48,000 - - $5,062
-
MMBtu
- -
10 2.9112: Use solar heat to heat water $20,496 $210,000 $12,390
193,600
kWh
- - - $8,106
TOTAL RECOMMENDED $47,359 $313,883 $14,075
219,939
kWh
$177
-
kW-mo/yr
$8,325
-
MMBtu
$16,676
-
Tgal
$8,106
TOTAL IMPLEMENTED $9,403 $51,490 $985
15,404
kWh
$93
-
kW-mo/yr
$8,325
-
MMBtu
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings LPG Savings Water Usage Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs