Assessment Year | 2017 |
---|---|
Principal Product | Injection Molded Automotive Assemblies |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3089: Plastics Products, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 210 |
Plant Area |
150,000
ft2
|
Annual Production | 42,913,338
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $441,512 | 8,843,946 |
kWh
|
$0.050 |
Electricity Demand | $395,865 | 20,650 |
kW-mo/yr
|
$19.17 |
Natural Gas | $41,083 | 7,362 |
MMBtu
|
$5.58 |
TOTAL YEARLY COSTS | $878,460 | |||
RECOMMENDED SAVINGS* | $23,236 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,972 | $3,000 |
$1,682
33,648
kWh
|
$1,290
-
kW-mo/yr
|
|
02 | 2.4322: Use or replace with energy efficient substitutes | $2,383 | $300 |
$2,383
47,659
kWh
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $931 | $1,500 |
$931
18,614
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $14,992 | $8,978 |
$8,415
168,300
kWh
|
$6,577
-
kW-mo/yr
|
|
05 | 2.7135: Install occupancy sensors | $1,958 | $2,400 |
$1,958
39,168
kWh
|
- | |
TOTAL RECOMMENDED | $23,236 | $16,178 |
$15,369
307,389
kWh
|
$7,867
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs