Assessment Year | 2017 |
---|---|
Principal Product | Guidance Systems |
NAICS | 334511: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical System and Instrument Manufactur |
SIC | 3812: Search, Detection, Navigation, Guidance, Aeronautical, and Nautical Systems and Instruments |
Sales Range | $100 M to 500M |
# of Employees | 550 |
Plant Area |
278,000
ft2
|
Annual Production | 10,000
units
|
Production Hrs. Annual | 8,424
hrs
|
Location (State) | Utah |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $740,863 | 19,696,800 |
kWh
|
$0.038 | |
Electricity Demand | $38,866 | 2,932 |
kW-mo/yr
|
$13.26 | |
Electricity Fees | $167,452 | - |
|
- | |
Natural Gas | $232,120 | 39,873 |
MMBtu
|
$5.82 | |
Waste Disposal Costs | |||||
Water Usage | $54,440 | 10,079 |
Tgal
|
$5.40 | |
TOTAL YEARLY COSTS | $1,233,740 | ||||
RECOMMENDED SAVINGS* | $155,178 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $69,808 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $57,965 | $96,413 |
$33,753
888,234
kWh
|
$17,816
-
kW-mo/yr
|
$6,396 | - | |
02 | 2.7144: Install spectral reflectors / delamp | $34,105 | $2,426 |
$20,676
544,093
kWh
|
$9,882
-
kW-mo/yr
|
$3,548 | - | |
03 | 2.5194: Redesign process | $25,877 | $35,010 |
$15,624
413,383
kWh
|
$7,544
-
kW-mo/yr
|
$2,709 | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $21,087 | $100 | - | - | - |
$21,087
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,843 | $1,647 |
$7,180
188,937
kWh
|
$3,431
-
kW-mo/yr
|
$1,232 | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,522 | - |
$2,333
61,401
kWh
|
$875
-
kW-mo/yr
|
$314 | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $779 | $1,695 |
$341
8,979
kWh
|
$322
-
kW-mo/yr
|
$116 | - | |
TOTAL RECOMMENDED | $155,178 | $137,292 |
$79,906
2,105,027
kWh
|
$39,870
-
kW-mo/yr
|
$14,315 |
$21,087
-
MMBtu
|
||
TOTAL IMPLEMENTED | $69,808 | $98,060 |
$40,933
1,077,171
kWh
|
$21,247
-
kW-mo/yr
|
$7,628 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs