Assessment Year | 2017 |
---|---|
Principal Product | Nutritional Supplements |
NAICS | 325412: Pharmaceutical Preparation Manufacturing |
SIC | 2833: Medicinal Chemicals and Botanical Products |
Sales Range | $10 M to 50M |
# of Employees | 130 |
Plant Area |
56,200
ft2
|
Annual Production | 5,000,000
lb
|
Production Hrs. Annual | 4,576
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $95,952 | 761,939 |
kWh
|
$0.13 |
Natural Gas | $8,814 | 1,501 |
MMBtu
|
$5.87 |
TOTAL YEARLY COSTS | $104,766 | |||
RECOMMENDED SAVINGS* | $19,277 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,508 | $500 |
$1,508
11,603
kWh
|
|
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,312 | $4,000 |
$17,312
133,168
kWh
|
|
03 | 2.7134: Use photocell controls | $457 | $200 |
$457
3,517
kWh
|
|
TOTAL RECOMMENDED | $19,277 | $4,700 |
$19,277
148,288
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs