| Assessment Year | 2016 |
|---|---|
| Principal Product | Hot End exhaust (manifold and catalytic converters) |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
109,000
ft2
|
| Annual Production | 300,000
units
|
| Production Hrs. Annual | 3,840
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $152,135 | 1,827,140 |
kWh
|
$0.083 |
| Natural Gas | $42,995 | 6,524 |
MMBtu
|
$6.59 |
| TOTAL YEARLY COSTS | $195,130 | |||
| RECOMMENDED SAVINGS* | $15,234 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,139 | $1,000 |
$2,139
25,771
kWh
|
- | |
| 02 | 2.7243: Improve air circulation with destratification fans / other methods | $2,118 | $5,200 |
$438
5,222
kWh
|
$1,680
-
MMBtu
|
|
| 03 | 2.2443: Re-use or recycle hot or cold process exhaust air | $7,961 | $20,000 | - |
$7,961
-
MMBtu
|
|
| 04 | 2.2437: Recover waste heat from equipment | $2,415 | $1,500 | - |
$2,415
-
MMBtu
|
|
| 05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $601 | $1,000 | - |
$601
-
MMBtu
|
|
| TOTAL RECOMMENDED | $15,234 | $28,700 |
$2,577
30,993
kWh
|
$12,657
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||