Assessment Year | 2013 |
---|---|
Principal Product | Hydrolic fittings coating |
NAICS | 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring |
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $5 M to 10M |
# of Employees | 65 |
Plant Area |
27,000
ft2
|
Annual Production | 85,000,000
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $227,000 | 2,600,000 |
kWh
|
$0.087 |
Natural Gas | $47,000 | 6,000 |
MMBtu
|
$7.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $123,858 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $2,260 | $350 |
$2,260
26,589
kWh
|
- | |
02 | 2.4239: Eliminate or reduce compressed air usage | $945 | $600 |
$945
10,738
kWh
|
- | |
03 | 2.4322: Use or replace with energy efficient substitutes | $22,608 | $7,500 |
$34,496
392,000
kWh
|
$(-11,888.0)
-
MMBtu
|
|
04 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $98,045 | $175,000 |
$173,302
1,956,000
kWh
|
$(-75,257.0)
-
MMBtu
|
|
TOTAL RECOMMENDED | $123,858 | $183,450 |
$211,003
2,385,327
kWh
|
$(-87,145.0)
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - |