Assessment Year 2002
Principal Product Custom Motorcycles
NAICS 336991: Motorcycle, Bicycle, and Parts Manufacturing
SIC 3751: Motorcycles, Bicycles, and Parts
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 200,000
ft2
Annual Production 1,600
pieces
Production Hrs. Annual 6,072
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $78,456 1,713,300
kWh
Electricity Demand $32,398 4,156
kW-mo/yr
Electricity Fees $3,904 -
Natural Gas $19,956 3,996
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $35,845 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $35,125

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Administrative Changes Savings Primary Raw Material Savings
01 3.5313: Increase amount of waste recovered for resale $27,670 $800 - - $25,000
-
Tgal
$(-2,530.0) $5,200 -
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $3,140 $200 $1,830
55,700
kWh
$1,310
-
kW-mo/yr
- - - -
03 2.8123: Pay utility bills on time $1,990 - - - - - - $1,990
04 2.7142: Utilize higher efficiency lamps and/or ballasts $1,740 $3,230 $680
20,687
kWh
$1,060
-
kW-mo/yr
- - - -
05 2.6218: Turn off equipment when not in use $370 - $370
11,510
kWh
- - - - -
06 2.4221: Install compressor air intakes in coolest locations $520 $145 $190
5,885
kWh
$330
-
kW-mo/yr
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $215 $445 $145
4,415
kWh
$70
-
kW-mo/yr
- - - -
08 2.7124: Make a practice of turning off lights when not needed $200 - $200
6,135
kWh
- - - - -
TOTAL RECOMMENDED $35,845 $4,820 $3,415
104,332
kWh
$2,770
-
kW-mo/yr
$25,000
-
Tgal
$(-2,530.0) $5,200 $1,990
TOTAL IMPLEMENTED $35,125 $4,675 $3,025
92,312
kWh
$2,440
-
kW-mo/yr
$25,000
-
Tgal
$(-2,530.0) $5,200 $1,990
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Personnel Changes Savings Administrative Changes Savings Primary Raw Material Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs