| Assessment Year | 2011 |
|---|---|
| Principal Product | stainless steel |
| NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
| SIC | 3429: Hardware, Not Elsewhere Classified |
| Sales Range | $50 M to 100M |
| # of Employees | 148 |
| Plant Area |
118,420
ft2
|
| Annual Production | 45,000,000
pieces
|
| Production Hrs. Annual | 6,864
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $182,401 | 3,892,000 |
kWh
|
$0.047 |
| Electricity Demand | $117,593 | 7,226 |
kW-mo/yr
|
$16.27 |
| Natural Gas | $32,000 | 3,450 |
MMBtu
|
$9.28 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $18,607 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,272 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4224: Upgrade controls on compressors | $5,033 | $200 |
$1,393
29,640
kWh
|
$3,640
-
kW-mo/yr
|
|
| 02 | 2.2437: Recover waste heat from equipment | $13,335 | $30,200 |
$13,335
283,720
kWh
|
- | |
| 03 | 2.6211: Conserve energy by efficient use of vending machines | $239 | $10 |
$239
5,100
kWh
|
- | |
| TOTAL RECOMMENDED | $18,607 | $30,410 |
$14,967
318,460
kWh
|
$3,640
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $5,272 | $210 |
$1,632
34,740
kWh
|
$3,640
-
kW-mo/yr
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs