Assessment Year | 2011 |
---|---|
Principal Product | Food Products |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $5 M to 10M |
# of Employees | 500 |
Plant Area |
700,000
ft2
|
Annual Production | 76,179,854
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $731,339 | 9,958,531 |
kWh
|
$0.073 |
Electricity Demand | $105,216 | 7,724 |
kW-mo/yr
|
$13.62 |
Natural Gas | $401,178 | 80,235 |
MMBtu
|
$5.00 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $100,430 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,563 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,168 | $54,459 |
$11,168
152,076
kWh
|
- | - | |
02 | 2.7135: Install occupancy sensors | $9,765 | $5,250 |
$9,765
132,996
kWh
|
- | - | |
03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,083 | $500 |
$1,421
19,351
kWh
|
$1,662
-
kW-mo/yr
|
- | |
04 | 2.4113: Install motor voltage controller on lightly loaded motors | $1,205 | $130 |
$960
13,070
kWh
|
$245
-
kW-mo/yr
|
- | |
05 | 2.4221: Install compressor air intakes in coolest locations | $781 | $1,000 |
$359
4,894
kWh
|
$422
-
kW-mo/yr
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $30,528 | $66,561 | - | - |
$30,528
-
MMBtu
|
|
07 | 2.2136: Install / repair insulation on steam lines | $10,240 | $13,740 | - | - |
$10,240
-
MMBtu
|
|
08 | 2.2414: Use waste heat from hot flue gases to preheat | $630 | $1,000 | - | - |
$630
-
MMBtu
|
|
09 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $33,030 | $37,825 | - | - |
$33,030
-
MMBtu
|
|
TOTAL RECOMMENDED | $100,430 | $180,465 |
$23,673
322,387
kWh
|
$2,329
-
kW-mo/yr
|
$74,428
-
MMBtu
|
||
TOTAL IMPLEMENTED | $21,563 | $60,709 |
$20,933
285,072
kWh
|
- |
$630
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs