ITAC Assessment: UM0361
ITAC logo
ITAC Assessment: UM0361
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2010
Principal Product Library Furniture
NAICS 337211: Wood Office Furniture Manufacturing
SIC 2531: Public Building and Related Furniture
Sales Range $10
M
to 50
M
# of Employees 126
Plant Area 139,000
ft2
Annual Production 172,388
pieces
Production Hrs. Annual 2,210
hrs
Location (State) Michigan

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $128,070 2,447,375
kWh
Electricity Demand $85,221 9,383
kW-mo/yr
Natural Gas $141,259 11,559
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $123,379 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $31,121

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 3.6123: Burn wood by-products for heat $79,685 $67,199 - - $79,685
-
MMBtu
02 2.2437: Recover waste heat from equipment $9,763 $100 - - $9,763
-
MMBtu
03 2.7142: Utilize higher efficiency lamps and/or ballasts $21,000 $31,000 $10,816
206
kWh
$10,184
-
kW-mo/yr
-
04 2.1233: Analyze flue gas for proper air/fuel ratio $3,484 $1,200 - - $3,484
-
MMBtu
05 2.7491: Insulate glazing, walls, ceilings, and roofs $2,810 $5,718 - - $2,810
-
MMBtu
06 2.2437: Recover waste heat from equipment $2,522 $600 - - $2,522
-
MMBtu
07 2.4231: Reduce the pressure of compressed air to the minimum required $2,227 $650 $1,147
21,921
kWh
$1,080
-
kW-mo/yr
-
08 2.7135: Install occupancy sensors $1,137 $5,520 $1,137
21,720
kWh
- -
09 2.2136: Install / repair insulation on steam lines $396 $400 - - $396
-
MMBtu
10 2.4221: Install compressor air intakes in coolest locations $355 $750 $182
3,484
kWh
$173
-
kW-mo/yr
-
TOTAL RECOMMENDED $123,379 $113,137 $13,282
47,331
kWh
$11,437
-
kW-mo/yr
$98,660
-
MMBtu
TOTAL IMPLEMENTED $31,121 $40,120 $13,282
47,331
kWh
$11,437
-
kW-mo/yr
$6,402
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings