Assessment Year | 2024 |
---|---|
Principal Product | Art Gallery and Teaching |
NAICS | 712110: Museums |
SIC | 8412: Museums and Art Galleries |
Sales Range | less than $500 k |
# of Employees | 50 |
Plant Area |
100,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Illinois |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $186,281 | 1,652,896 |
kWh
|
$0.11 | |
Natural Gas | $21,286 | 4,257 |
MMBtu
|
$5.00 | |
Waste Disposal Costs | |||||
Water Usage | $8,852 | 975 |
Tgal
|
$9.08 | |
TOTAL YEARLY COSTS | $216,420 | ||||
RECOMMENDED SAVINGS* | $43,624 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $832 | $1,522 |
$891
8,100
kWh
|
$(-58.8)
-
MMBtu
|
|
02 | 2.7444: Close holes and openings in building such as broken windows | $62 | $288 | - |
$62
-
MMBtu
|
|
03 | 2.7144: Install spectral reflectors / delamp | $369 | $422 |
$395
3,592
kWh
|
$(-26.1)
-
MMBtu
|
|
04 | 2.4324: Replace hydraulic / pneumatic equipment with electric equipment | $146 | $490 |
$146
1,330
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,604 | $2,986 |
$1,604
14,582
kWh
|
- | |
06 | 2.7229: Air condition only space necessary | $1,564 | $5,300 |
$1,472
13,024
kWh
|
$92
-
MMBtu
|
|
07 | 2.7135: Install occupancy sensors | $1,657 | - |
$1,657
14,695
kWh
|
- | |
08 | 2.9114: Use solar heat to make electricty | $30,752 | $190,030 |
$30,752
279,559
kWh
|
- | |
09 | 2.7425: Clean or color roof to reduce solar load | $5,885 | $12,020 |
$5,885
53,496
kWh
|
- | |
10 | 2.6212: Turn off equipment during breaks, reduce operating time | $754 | - |
$754
6,851
kWh
|
- | |
TOTAL RECOMMENDED | $43,624 | $213,058 |
$43,555
395,228
kWh
|
$69
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs