Assessment Year | 2009 |
---|---|
Principal Product | Coal feeders and spouts |
NAICS | 332510: Hardware Manufacturing |
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $1 M to 5M |
# of Employees | 83 |
Plant Area |
140,000
ft2
|
Annual Production | 1
units
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,707 | 1,361,040 |
kWh
|
$0.050 |
Electricity Demand | $68,368 | 3,991 |
kW-mo/yr
|
$17.13 |
Natural Gas | $361,094 | 32,619 |
MMBtu
|
$11.07 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $172,435 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $172,435 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7494: Install storm windows and doors | $88,261 | $361,980 | - | - |
$88,261
-
MMBtu
|
|
02 | 2.7231: Use radiant heater for spot heating | $48,733 | $25,000 | - | - |
$48,733
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $17,053 | $42,818 |
$6,467
128,112
kWh
|
$10,586
-
kW-mo/yr
|
- | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $5,524 | $2,591 | - | - |
$5,524
-
MMBtu
|
|
05 | 2.2136: Install / repair insulation on steam lines | $1,523 | $1,359 | - | - |
$1,523
-
MMBtu
|
|
06 | 2.7135: Install occupancy sensors | $1,466 | $4,692 |
$1,466
34,510
kWh
|
- | - | |
07 | 2.4226: Use / purchase optimum sized compressor | $9,875 | $7,500 |
$3,811
81,847
kWh
|
$6,064
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $172,435 | $445,940 |
$11,744
244,469
kWh
|
$16,650
-
kW-mo/yr
|
$144,041
-
MMBtu
|
||
TOTAL IMPLEMENTED | $172,435 | $445,940 |
$11,744
244,469
kWh
|
$16,650
-
kW-mo/yr
|
$144,041
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs