Assessment Year | 2006 |
---|---|
Principal Product | Automotive Climate Control Assemblies |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | n/a |
# of Employees | 1,500 |
Plant Area |
1,000,000
ft2
|
Annual Production | 0
pieces
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,128,000 | 43,352,400 |
kWh
|
$0.026 |
Electricity Demand | $1,092,107 | 85,420 |
kW-mo/yr
|
$12.79 |
Electricity Fees | $49,132 | - |
|
- |
Natural Gas | $1,526,362 | 170,163 |
MMBtu
|
$8.97 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $135,839 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,436 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $62,424 | $69,750 |
$(-2,123.0)
(-81,592)
kWh
|
$(-1,903.0)
-
kW-mo/yr
|
$66,450
-
MMBtu
|
|
02 | 2.3112: Store heated/ cooled water for use during peak demand periods | $30,865 | $25,000 | - |
$30,865
-
kW-mo/yr
|
- | |
03 | 2.7444: Close holes and openings in building such as broken windows | $12,963 | $2,480 | - | - |
$12,963
-
MMBtu
|
|
04 | 2.4239: Eliminate or reduce compressed air usage | $12,296 | $7,000 |
$6,880
264,428
kWh
|
$5,416
-
kW-mo/yr
|
- | |
05 | 2.7447: Install vinyl strip / high speed / air curtain doors | $9,136 | $3,084 | - | - |
$9,136
-
MMBtu
|
|
06 | 2.7111: Reduce illumination to minimum necessary levels | $4,473 | $400 |
$4,473
171,924
kWh
|
- | - | |
07 | 2.2414: Use waste heat from hot flue gases to preheat | $2,953 | $3,286 | - | - |
$2,953
-
MMBtu
|
|
08 | 2.2414: Use waste heat from hot flue gases to preheat | $596 | $660 |
$596
11,464
kWh
|
- | - | |
09 | 2.7111: Reduce illumination to minimum necessary levels | $133 | $175 |
$133
5,107
kWh
|
- | - | |
TOTAL RECOMMENDED | $135,839 | $111,835 |
$9,959
371,331
kWh
|
$34,378
-
kW-mo/yr
|
$91,502
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,436 | $2,880 |
$4,473
171,924
kWh
|
- |
$12,963
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs