Assessment Year | 2006 |
---|---|
Principal Product | cement type I & III |
NAICS | 327310: Cement Manufacturing |
SIC | 3241: Cement, Hydraulic |
Sales Range | $50 M to 100M |
# of Employees | 150 |
Plant Area |
2,633,400
ft2
|
Annual Production | 920,000
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $3,606,023 | 129,964,880 |
kWh
|
$0.028 |
Electricity Demand | $2,184,220 | 108,000 |
kW-mo/yr
|
$20.22 |
Electricity Fees | $9,702 | - |
|
- |
Natural Gas | $755,250 | 1,794,920 |
MMBtu
|
$0.42 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $358,171 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,914 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|
01 | 2.2437: Recover waste heat from equipment | $338,489 | $344,200 |
$180,776
6,514,450
kWh
|
$180,928
-
kW-mo/yr
|
$(-23,215.0)
-
Tgal
|
|
02 | 2.4221: Install compressor air intakes in coolest locations | $7,914 | $1,100 |
$2,819
101,590
kWh
|
$5,095
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,020 | $7,545 |
$3,009
108,422
kWh
|
$3,011
-
kW-mo/yr
|
- | |
04 | 2.7124: Make a practice of turning off lights when not needed | $3,089 | $1,000 |
$1,985
71,548
kWh
|
$1,104
-
kW-mo/yr
|
- | |
05 | 2.7135: Install occupancy sensors | $2,659 | $552 |
$2,659
95,830
kWh
|
- | - | |
TOTAL RECOMMENDED | $358,171 | $354,397 |
$191,248
6,891,840
kWh
|
$190,138
-
kW-mo/yr
|
$(-23,215.0)
-
Tgal
|
||
TOTAL IMPLEMENTED | $7,914 | $1,100 |
$2,819
101,590
kWh
|
$5,095
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs