Assessment Year | 1998 |
---|---|
Principal Product | Marketing Displays |
NAICS |
n/a
|
SIC | 3993: Signs and Advertising Specialties |
Sales Range | $10 M to 50M |
# of Employees | 186 |
Plant Area |
80,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,562 | 1,382,767 |
kWh
|
$0.059 |
Electricity Demand | $47,888 | 3,828 |
kW-mo/yr
|
$12.51 |
Electricity Fees | $11,115 | - |
|
- |
Natural Gas | $17,438 | 4,166 |
MMBtu
|
$4.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,892 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $21,538 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Fees Savings | Natural Gas Savings | Personnel Changes Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $17,244 | $40,250 | $17,244 | - | - | - | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,032 | $1,035 | - |
$4,032
-
MMBtu
|
- | - | |
03 | 2.7231: Use radiant heater for spot heating | $3,876 | $2,400 | - |
$3,876
-
MMBtu
|
- | - | |
04 | 3.4111: Use closed cycle process to minimize waste water production | $418 | $500 | - | - | - |
$418
-
Tgal
|
|
05 | 4.451: Add additional production shift | $4,322 | - | - | - | $4,322 | - | |
TOTAL RECOMMENDED | $29,892 | $44,185 | $17,244 |
$7,908
-
MMBtu
|
$4,322 |
$418
-
Tgal
|
||
TOTAL IMPLEMENTED | $21,538 | $43,150 | $17,244 |
$3,876
-
MMBtu
|
- |
$418
-
Tgal
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs