Assessment Year | 2006 |
---|---|
Principal Product | Metal Stamping: Automotive Parts |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 193 |
Plant Area |
250,625
ft2
|
Annual Production | 18,755,862
pieces
|
Production Hrs. Annual | 5,100
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $382,377 | 10,935,120 |
kWh
|
$0.035 |
Electricity Demand | $368,352 | 23,253 |
kW-mo/yr
|
$15.84 |
Electricity Fees | $53,485 | - |
|
- |
Natural Gas | $1,714,486 | 20,068 |
MMBtu
|
$85.43 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $86,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $84,965 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $36,291 | $720 | - | - |
$36,291
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,496 | $8,700 |
$8,951
255,952
kWh
|
$9,545
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,108 | $9,353 |
$5,793
166,511
kWh
|
$7,315
-
kW-mo/yr
|
- | |
04 | 2.7111: Reduce illumination to minimum necessary levels | $11,706 | $738 |
$6,243
179,437
kWh
|
$5,463
-
kW-mo/yr
|
- | |
05 | 2.7442: Keep doors and windows shut when not on use | $5,156 | $25 | - | - |
$5,156
-
MMBtu
|
|
06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,389 | $2,750 | - | - |
$1,389
-
MMBtu
|
|
07 | 2.7145: Install skylights | $208 | $184 |
$208
5,974
kWh
|
- | - | |
TOTAL RECOMMENDED | $86,354 | $22,470 |
$21,195
607,874
kWh
|
$22,323
-
kW-mo/yr
|
$42,836
-
MMBtu
|
||
TOTAL IMPLEMENTED | $84,965 | $19,720 |
$21,195
607,874
kWh
|
$22,323
-
kW-mo/yr
|
$41,447
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs