| Assessment Year | 2006 |
|---|---|
| Principal Product | Metal Stamping: Automotive Parts |
| NAICS | 336370: Motor Vehicle Metal Stamping |
| SIC | 3465: Automotive Stampings |
| Sales Range | $10 M to 50M |
| # of Employees | 193 |
| Plant Area |
250,625
ft2
|
| Annual Production | 18,755,862
pieces
|
| Production Hrs. Annual | 5,100
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $382,377 | 10,935,120 |
kWh
|
$0.035 |
| Electricity Demand | $368,352 | 23,253 |
kW-mo/yr
|
$15.84 |
| Electricity Fees | $53,485 | - |
|
- |
| Natural Gas | $1,714,486 | 20,068 |
MMBtu
|
$85.43 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $86,354 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $84,965 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $36,291 | $720 | - | - |
$36,291
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $18,496 | $8,700 |
$8,951
255,952
kWh
|
$9,545
-
kW-mo/yr
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,108 | $9,353 |
$5,793
166,511
kWh
|
$7,315
-
kW-mo/yr
|
- | |
| 04 | 2.7111: Reduce illumination to minimum necessary levels | $11,706 | $738 |
$6,243
179,437
kWh
|
$5,463
-
kW-mo/yr
|
- | |
| 05 | 2.7442: Keep doors and windows shut when not on use | $5,156 | $25 | - | - |
$5,156
-
MMBtu
|
|
| 06 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $1,389 | $2,750 | - | - |
$1,389
-
MMBtu
|
|
| 07 | 2.7145: Install skylights | $208 | $184 |
$208
5,974
kWh
|
- | - | |
| TOTAL RECOMMENDED | $86,354 | $22,470 |
$21,195
607,874
kWh
|
$22,323
-
kW-mo/yr
|
$42,836
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $84,965 | $19,720 |
$21,195
607,874
kWh
|
$22,323
-
kW-mo/yr
|
$41,447
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs