Assessment Year | 2016 |
---|---|
Principal Product | Aerospace Components |
NAICS | 336413: Other Aircraft Parts and Auxiliary Equipment Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 268 |
Plant Area |
98,000
ft2
|
Annual Production | 100,000
units
|
Production Hrs. Annual | 6,552
hrs
|
Location (State) | California |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $468,702 | 5,922,724 |
kWh
|
$0.079 |
Electricity Demand | $323,644 | 16,406 |
kW-mo/yr
|
$19.73 |
Electricity Fees | $13,703 | - |
|
- |
Natural Gas | $105,900 | 14,120 |
MMBtu
|
$7.50 |
TOTAL YEARLY COSTS | $911,949 | |||
RECOMMENDED SAVINGS* | $36,026 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,543 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,781 | $24,125 |
$8,717
110,215
kWh
|
$4,064
-
kW-mo/yr
|
- | |
02 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $5,588 | $3,308 | - | - |
$5,588
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,174 | $2,000 |
$4,893
61,862
kWh
|
$281
-
kW-mo/yr
|
- | |
04 | 2.7491: Insulate glazing, walls, ceilings, and roofs | $4,855 | $6,757 |
$3,864
48,851
kWh
|
$991
-
kW-mo/yr
|
- | |
05 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $3,169 | $11,200 |
$1,624
20,530
kWh
|
$1,545
-
kW-mo/yr
|
- | |
06 | 2.7134: Use photocell controls | $2,137 | $4,625 |
$2,137
27,014
kWh
|
- | - | |
07 | 2.4237: Substitute compressed air cooling with water or air cooling | $1,177 | $305 |
$654
8,270
kWh
|
$523
-
kW-mo/yr
|
- | |
08 | 2.4239: Eliminate or reduce compressed air usage | $1,145 | $850 |
$632
7,995
kWh
|
$513
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $36,026 | $53,170 |
$22,521
284,737
kWh
|
$7,917
-
kW-mo/yr
|
$5,588
-
MMBtu
|
||
TOTAL IMPLEMENTED | $23,543 | $29,433 |
$13,610
172,077
kWh
|
$4,345
-
kW-mo/yr
|
$5,588
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs