| Assessment Year | 2006 |
|---|---|
| Principal Product | Precision Machined Automotive Parts |
| NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $50 M to 100M |
| # of Employees | 256 |
| Plant Area |
125,865
ft2
|
| Annual Production | 5,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $408,148 | 11,522,946 |
kWh
|
$0.035 |
| Electricity Demand | $228,462 | 24,425 |
kW-mo/yr
|
$9.35 |
| Electricity Fees | $3,134 | - |
|
- |
| Natural Gas | $11,537 | 2,260 |
MMBtu
|
$5.10 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $34,401 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $14,391 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $8,060 | $2,000 | - | - |
$8,060
-
MMBtu
|
|
| 02 | 2.2511: Insulate bare equipment | $6,448 | $9,089 |
$6,448
115,149
kWh
|
- | - | |
| 03 | 2.7444: Close holes and openings in building such as broken windows | $6,156 | $3,450 | - | - |
$6,156
-
MMBtu
|
|
| 04 | 2.7442: Keep doors and windows shut when not on use | $5,502 | $3,900 | - | - |
$5,502
-
MMBtu
|
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $5,020 | $872 |
$4,727
133,432
kWh
|
$293
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,215 | $6,601 |
$2,062
58,203
kWh
|
$1,153
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $34,401 | $25,912 |
$13,237
306,784
kWh
|
$1,446
-
kW-mo/yr
|
$19,718
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $14,391 | $10,923 |
$6,789
191,635
kWh
|
$1,446
-
kW-mo/yr
|
$6,156
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs