Assessment Year | 2006 |
---|---|
Principal Product | Precision Springs and Stampings |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | n/a |
# of Employees | 79 |
Plant Area |
40,000
ft2
|
Annual Production | 2,000,000
lb
|
Production Hrs. Annual | 4,250
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $75,752 | 910,800 |
kWh
|
$0.083 |
Electricity Demand | $15,981 | 2,388 |
kW-mo/yr
|
$6.69 |
Electricity Fees | $3,320 | - |
|
- |
Natural Gas | $19,820 | 2,022 |
MMBtu
|
$9.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,149 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $4,716 | $50 |
$4,716
56,678
kWh
|
- | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,647 | $3,688 |
$2,157
25,921
kWh
|
$490
-
kW-mo/yr
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,389 | $75 |
$2,054
24,693
kWh
|
$335
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,352 | $400 |
$(-46.0)
(-442)
kWh
|
$6
-
kW-mo/yr
|
$1,392
-
MMBtu
|
|
05 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $1,144 | $392 |
$(-42.0)
500
kWh
|
$(-10.0)
-
kW-mo/yr
|
$1,196
-
MMBtu
|
|
06 | 2.4221: Install compressor air intakes in coolest locations | $646 | $200 |
$556
6,691
kWh
|
$90
-
kW-mo/yr
|
- | |
07 | 2.7135: Install occupancy sensors | $255 | $92 |
$255
3,063
kWh
|
- | - | |
TOTAL RECOMMENDED | $13,149 | $4,897 |
$9,650
117,104
kWh
|
$911
-
kW-mo/yr
|
$2,588
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs