Assessment Year | 2004 |
---|---|
Principal Product | Commercial Kitchen Cooking and Preparation Equipment |
NAICS | 333318: Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3589: Service Industry Machinery, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 432 |
Plant Area |
360,000
ft2
|
Annual Production | 8,000,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Indiana |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $258,834 | 7,927,289 |
kWh
|
$0.033 |
Electricity Demand | $139,701 | 19,038 |
kW-mo/yr
|
$7.34 |
Electricity Fees | $1,115 | - |
|
- |
Natural Gas | $332,341 | 46,531 |
MMBtu
|
$7.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,052 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $17,237 | $600 | - | - |
$17,237
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,834 | $1,275 |
$6,803
206,261
kWh
|
$3,031
-
kW-mo/yr
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,913 | $2,890 |
$4,703
144,057
kWh
|
$1,210
-
kW-mo/yr
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $3,128 | $3,000 | - | - |
$3,128
-
MMBtu
|
|
05 | 2.4239: Eliminate or reduce compressed air usage | $1,435 | $2,000 |
$993
30,093
kWh
|
$442
-
kW-mo/yr
|
- | |
06 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,285 | $400 |
$1,285
39,344
kWh
|
- | - | |
07 | 2.7135: Install occupancy sensors | $220 | $276 |
$220
6,678
kWh
|
- | - | |
TOTAL RECOMMENDED | $39,052 | $10,441 |
$14,004
426,433
kWh
|
$4,683
-
kW-mo/yr
|
$20,365
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs