| Assessment Year | 2004 |
|---|---|
| Principal Product | Plastic Bottles |
| NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
| SIC | 3085: Plastics Bottles |
| Sales Range | $50 M to 100M |
| # of Employees | 287 |
| Plant Area |
176,000
ft2
|
| Annual Production | 400,000,000
pieces
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $2,332,899 | 52,500,335 |
kWh
|
$0.044 |
| Electricity Demand | $432,085 | 93,360 |
kW-mo/yr
|
$4.63 |
| Electricity Fees | $(-48,152.0) | - |
|
- |
| Natural Gas | $149,398 | 27,626 |
MMBtu
|
$5.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $171,990 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7233: Use properly designed and sized hvac equipment | $105,689 | $64,000 | n/a |
$98,344
2,164,739
kWh
|
$7,345
-
kW-mo/yr
|
- |
| 02 | 2.2437: Recover waste heat from equipment | $30,525 | $30,000 | n/a | - | - |
$30,525
-
MMBtu
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,733 | $15,532 | n/a |
$10,800
237,727
kWh
|
$933
-
kW-mo/yr
|
- |
| 04 | 2.4323: Use optimum size and capacity equipment | $11,886 | $30,000 | n/a |
$11,060
243,469
kWh
|
$826
-
kW-mo/yr
|
- |
| 05 | 2.2491: Use cooling air which cools hot work pieces for space heating | $6,581 | $10,000 | n/a | - | - |
$6,581
-
MMBtu
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,069 | $975 |
$2,779
61,161
kWh
|
$290
-
kW-mo/yr
|
- | |
| 07 | 2.7444: Close holes and openings in building such as broken windows | $1,652 | $250 | - | - |
$1,652
-
MMBtu
|
|
| 08 | 2.2514: Cover open tanks | $855 | $1,500 |
$796
17,524
kWh
|
$59
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $171,990 | $152,257 |
$123,779
2,724,620
kWh
|
$9,453
-
kW-mo/yr
|
$38,758
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs