| Assessment Year | 2002 |
|---|---|
| Principal Product | Aerospace electronics, indicators for cockpits and flap position sensors |
| NAICS |
n/a
|
| SIC | 3826: Laboratory Analytical Instruments |
| Sales Range | $10 M to 50M |
| # of Employees | 195 |
| Plant Area |
66,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $139,725 | 3,191,569 |
kWh
|
$0.044 |
| Electricity Demand | $81,852 | 7,180 |
kW-mo/yr
|
$11.40 |
| Electricity Fees | $2,473 | - |
|
- |
| Natural Gas | $18,965 | 3,726 |
MMBtu
|
$5.09 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $119,171 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,066 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $78,674 | $26,400 | n/a |
$54,191
1,328,868
kWh
|
$24,483
-
kW-mo/yr
|
- | - | - |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,965 | $62,826 |
$11,273
276,432
kWh
|
$12,120
-
kW-mo/yr
|
- |
$2,572
-
lb
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $283 | $225 |
$184
4,514
kWh
|
$99
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $431 | $600 |
$280
6,869
kWh
|
$151
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.6218: Turn off equipment when not in use | $1,258 | $800 |
$1,258
16,480
kWh
|
- | - | - | - | |
| 06 | 2.1224: Replace boiler | $3,920 | $12,000 | - | - |
$3,920
-
MMBtu
|
- | - | |
| 07 | 3.4115: Recover and reuse cooling water | $8,640 | $5,940 | - | - | - | - |
$8,640
-
Tgal
|
|
| TOTAL RECOMMENDED | $119,171 | $108,791 |
$67,186
1,633,163
kWh
|
$36,853
-
kW-mo/yr
|
$3,920
-
MMBtu
|
$2,572
-
lb
|
$8,640
-
Tgal
|
||
| TOTAL IMPLEMENTED | $40,066 | $81,791 |
$12,715
297,426
kWh
|
$12,219
-
kW-mo/yr
|
$3,920
-
MMBtu
|
$2,572
-
lb
|
$8,640
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs