Assessment Year | 2000 |
---|---|
Principal Product | Titanium tubing |
NAICS |
n/a
|
SIC | 3498: Fabricated Pipe and Pipe Fittings |
Sales Range | $5 M to 10M |
# of Employees | 86 |
Plant Area |
109,000
ft2
|
Annual Production | 620
thousand feet
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $68,706 | 2,178,488 |
kWh
|
$0.032 |
Electricity Demand | $80,561 | 4,248 |
kW-mo/yr
|
$18.96 |
Electricity Fees | $8,860 | - |
|
- |
Natural Gas | $69,583 | 18,956 |
MMBtu
|
$3.67 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,177 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $1,108 | $4,665 |
$567
19,050
kWh
|
$541
-
kW-mo/yr
|
- | - | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,795 | $100 |
$926
31,360
kWh
|
$869
-
kW-mo/yr
|
- | - | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,504 | $825 |
$1,980
66,823
kWh
|
$1,524
-
kW-mo/yr
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $1,167 | $500 | - | - |
$1,167
-
MMBtu
|
- | - | |
05 | 2.7243: Improve air circulation with destratification fans / other methods | $20,700 | $4,550 | - | - |
$20,700
-
MMBtu
|
- | - | |
06 | 2.2511: Insulate bare equipment | $6,118 | $3,300 | - | - |
$6,118
-
MMBtu
|
- | - | |
07 | 3.4111: Use closed cycle process to minimize waste water production | $16,497 | $1,000 | - | - | - |
$16,497
-
Tgal
|
- | |
08 | 3.3122: Use filtration, centrifuging to remove contaminants | $7,288 | $11,000 | - | - | - | - |
$7,288
-
gal
|
|
TOTAL RECOMMENDED | $58,177 | $25,940 |
$3,473
117,233
kWh
|
$2,934
-
kW-mo/yr
|
$27,985
-
MMBtu
|
$16,497
-
Tgal
|
$7,288
-
gal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs