Assessment Year | 1999 |
---|---|
Principal Product | Pnuematic Hand Tools |
NAICS |
n/a
|
SIC | 3546: Power-Driven Handtools |
Sales Range | $10 M to 50M |
# of Employees | 121 |
Plant Area |
90,000
ft2
|
Annual Production | 8,000
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $53,872 | 2,530,481 |
kWh
|
$0.021 |
Electricity Demand | $77,245 | 7,488 |
kW-mo/yr
|
$10.32 |
Electricity Fees | $742 | - |
|
- |
Natural Gas | $14,857 | 2,722 |
MMBtu
|
$5.46 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $44,714 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $680 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,828 | $1,500 |
$410
62,134
kWh
|
$1,418
-
kW-mo/yr
|
- | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $680 | $300 |
$157
23,154
kWh
|
$523
-
kW-mo/yr
|
- | - | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $3,067 | $880 |
$1,440
67,702
kWh
|
$1,627
-
kW-mo/yr
|
- | - | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,923 | $1,750 | - | - |
$3,923
-
MMBtu
|
- | - | |
05 | 3.3128: Utilize other methods to remove contaminants | $35,216 | $50,000 | - | - | - | $34,110 | $1,106 | |
TOTAL RECOMMENDED | $44,714 | $54,430 |
$2,007
152,990
kWh
|
$3,568
-
kW-mo/yr
|
$3,923
-
MMBtu
|
$34,110 | $1,106 | ||
TOTAL IMPLEMENTED | $680 | $300 |
$157
23,154
kWh
|
$523
-
kW-mo/yr
|
- | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs