| Assessment Year | 1999 |
|---|---|
| Principal Product | Abrasive Tumbling Media |
| NAICS |
n/a
|
| SIC | 3291: Abrasive Products |
| Sales Range | $1 M to 5M |
| # of Employees | 25 |
| Plant Area |
70,000
ft2
|
| Annual Production | 6,000,000
lb
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $62,374 | 900,059 |
kWh
|
$0.069 |
| Electricity Demand | $18,744 | 1,488 |
kW-mo/yr
|
$12.60 |
| Electricity Fees | $(-766.0) | - |
|
- |
| Natural Gas | $159,684 | 45,118 |
MMBtu
|
$3.54 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $48,049 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $40,364 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7111: Reduce illumination to minimum necessary levels | $1,661 | $110 |
$1,661
16,706
kWh
|
- | - | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $647 | $1,000 |
$497
7,913
kWh
|
$150
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,285 | $350 |
$988
15,826
kWh
|
$297
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.1122: Re-size charging openings or add a movable door on equipment | $5,837 | $9,350 | - | - |
$5,837
-
MMBtu
|
- | - | |
| 05 | 2.2515: Use optimum thickness insulation | $1,848 | $2,100 | - | - |
$1,848
-
MMBtu
|
- | - | |
| 06 | 3.1192: Reduce scrap production | $29,091 | $5,000 | - | - | - |
$29,091
-
lb
|
- | |
| 07 | 4.444: Install system to collect scrap | $7,680 | $584 | - | - | - | - | $7,680 | |
| TOTAL RECOMMENDED | $48,049 | $18,494 |
$3,146
40,445
kWh
|
$447
-
kW-mo/yr
|
$7,685
-
MMBtu
|
$29,091
-
lb
|
$7,680 | ||
| TOTAL IMPLEMENTED | $40,364 | $7,044 |
$3,146
40,445
kWh
|
$447
-
kW-mo/yr
|
- |
$29,091
-
lb
|
$7,680 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs