Assessment Year | 1999 |
---|---|
Principal Product | Wrought Iron Furniture |
NAICS |
n/a
|
SIC | 2514: Metal Household Furniture |
Sales Range | $10 M to 50M |
# of Employees | 262 |
Plant Area |
44,000
ft2
|
Annual Production | 3,744
ton
|
Production Hrs. Annual | 6,084
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $166,519 | 4,925,264 |
kWh
|
$0.034 |
Electricity Demand | $108,372 | 12,744 |
kW-mo/yr
|
$8.50 |
Electricity Fees | $42,086 | - |
|
- |
Natural Gas | $159,208 | 45,267 |
MMBtu
|
$3.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $987,653 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4221: Install compressor air intakes in coolest locations | $1,206 | $1,000 |
$817
25,791
kWh
|
$389
-
kW-mo/yr
|
- | - | - | |
02 | 2.1121: Use insulation in furnaces to facilitate heating / cooling | $11,967 | $2,000 |
$5,263
166,178
kWh
|
$6,704
-
kW-mo/yr
|
- | - | - | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $27,764 | $36,550 | - | - |
$27,764
-
MMBtu
|
- | - | |
04 | 3.5212: Regrind, reuse, or sell scrap plastic parts | $1,800 | - | - | - | - |
$1,800
-
lb
|
- | |
05 | 4.111: Add equipment/ operators to reduce production bottleneck | $944,916 | $200,000 | - | - | - | - | $944,916 | |
TOTAL RECOMMENDED | $987,653 | $239,550 |
$6,080
191,969
kWh
|
$7,093
-
kW-mo/yr
|
$27,764
-
MMBtu
|
$1,800
-
lb
|
$944,916 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs