| Assessment Year | 2006 |
|---|---|
| Principal Product | dome structures |
| NAICS | 332311: Prefabricated Metal Building and Component Manufacturing |
| SIC | 3448: Prefabricated Metal Buildings and Components |
| Sales Range | $10 M to 50M |
| # of Employees | 53 |
| Plant Area |
95,000
ft2
|
| Annual Production | 200
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Georgia |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $98,587 | 1,886,523 |
kWh
|
$0.052 |
| Electricity Demand | $26,670 | 2,610 |
kW-mo/yr
|
$10.22 |
| Electricity Fees | $25,535 | - |
|
- |
| Natural Gas | $55,299 | 2,562 |
MMBtu
|
$21.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,206 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,555 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.8114: Change rate schedules or other changes in utility service | $8,555 | - | - | - | $8,555 | |
| 02 | 2.8114: Change rate schedules or other changes in utility service | $3,095 | $13,342 | - | - | $3,095 | |
| 03 | 2.7135: Install occupancy sensors | $454 | $280 |
$454
8,702
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,167 | $23,331 |
$4,617
88,358
kWh
|
$2,550
-
kW-mo/yr
|
- | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $746 | $400 |
$470
8,993
kWh
|
$276
-
kW-mo/yr
|
- | |
| 06 | 2.8112: Combine utility meters | $2,907 | $7,120 | - | - | $2,907 | |
| 07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $282 | $234 |
$140
2,672
kWh
|
$142
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $23,206 | $44,707 |
$5,681
108,725
kWh
|
$2,968
-
kW-mo/yr
|
$14,557 | ||
| TOTAL IMPLEMENTED | $8,555 | - | - | - | $8,555 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs