Assessment Year | 1998 |
---|---|
Principal Product | Food Procesing Equipment |
NAICS |
n/a
|
SIC | 3550: |
Sales Range | $10 M to 50M |
# of Employees | 122 |
Plant Area |
45,935
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 6,732
hrs
|
Location (State) | Ohio |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $79,143 | 2,533,705 |
kWh
|
$0.031 |
Electricity Demand | $99,616 | 5,472 |
kW-mo/yr
|
$18.20 |
Electricity Fees | $3,329 | - |
|
- |
Natural Gas | $18,229 | 2,967 |
MMBtu
|
$6.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,993 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $45,723 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $3,418 | $2,142 |
$2,356
32,825
kWh
|
$1,062
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $20,663 | $25,773 |
$11,709
161,782
kWh
|
$8,954
-
kW-mo/yr
|
- | - | - | |
03 | 2.7447: Install vinyl strip / high speed / air curtain doors | $436 | $650 | - | - |
$436
-
MMBtu
|
- | - | |
04 | 2.7243: Improve air circulation with destratification fans / other methods | $3,162 | $960 | - | - |
$3,162
-
MMBtu
|
- | - | |
05 | 3.3131: Use evaporation to concentrate material | $7,020 | $16,000 | - | - | - |
$7,020
-
Tgal
|
- | |
06 | 3.3122: Use filtration, centrifuging to remove contaminants | $3,814 | $11,000 | - | - | - |
$3,814
-
Tgal
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,000 | $1,554 | - | - | - | - | $15,000 | |
08 | 4.515: Install shelves / racks to utilize unused space | $3,480 | $3,342 | - | - | - | - | $3,480 | |
TOTAL RECOMMENDED | $56,993 | $61,421 |
$14,065
194,607
kWh
|
$10,016
-
kW-mo/yr
|
$3,598
-
MMBtu
|
$10,834
-
Tgal
|
$18,480 | ||
TOTAL IMPLEMENTED | $45,723 | $33,771 |
$14,065
194,607
kWh
|
$10,016
-
kW-mo/yr
|
$3,162
-
MMBtu
|
- | $18,480 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs