Assessment Year | 1997 |
---|---|
Principal Product | Automotive Stampings and Assemblies |
NAICS |
n/a
|
SIC | 3465: Automotive Stampings |
Sales Range | $10 M to 50M |
# of Employees | 263 |
Plant Area |
124,502
ft2
|
Annual Production | 2,893,000
units
|
Production Hrs. Annual | 6,600
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $125,625 | 4,233,001 |
kWh
|
$0.030 |
Electricity Demand | $165,858 | 9,444 |
kW-mo/yr
|
$17.56 |
Electricity Fees | $(-664.0) | - |
|
- |
Natural Gas | $74,676 | 15,830 |
MMBtu
|
$4.72 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $59,144 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,941 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,265 | $28,912 |
$3,874
131,008
kWh
|
$3,391
-
kW-mo/yr
|
- | |
02 | 2.7124: Make a practice of turning off lights when not needed | $378 | - |
$378
17,292
kWh
|
- | - | |
03 | 2.4221: Install compressor air intakes in coolest locations | $6,676 | $2,400 |
$3,401
114,889
kWh
|
$3,275
-
kW-mo/yr
|
- | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,306 | $16,063 |
$4,306
334,701
kWh
|
- | - | |
05 | 4.513: Re-arrange equipment layout to reduce labor costs | $40,519 | $38 | - | - | $40,519 | |
TOTAL RECOMMENDED | $59,144 | $47,413 |
$11,959
597,890
kWh
|
$6,666
-
kW-mo/yr
|
$40,519 | ||
TOTAL IMPLEMENTED | $13,941 | $31,312 |
$7,275
245,897
kWh
|
$6,666
-
kW-mo/yr
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs