| Assessment Year | 1997 |
|---|---|
| Principal Product | Agricultural Tillage Tools |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 63 |
| Plant Area |
113,862
ft2
|
| Annual Production | 5,000,000
units
|
| Production Hrs. Annual | 3,854
hrs
|
| Location (State) | Ohio |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $200,745 | 4,040,152 |
kWh
|
$0.050 |
| Electricity Demand | $86,517 | 22,140 |
kW-mo/yr
|
$3.91 |
| Electricity Fees | $9,039 | - |
|
- |
| Natural Gas | $155,295 | 38,243 |
MMBtu
|
$4.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $67,883 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $19,580 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $706 | $1,185 |
$377
8,499
kWh
|
$329
-
kW-mo/yr
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,560 | $22,835 |
$1,336
30,481
kWh
|
$1,224
-
kW-mo/yr
|
- | - | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,236 | $1,000 |
$667
5,275
kWh
|
$569
-
kW-mo/yr
|
- | - | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $5,407 | $2,520 |
$2,527
76,788
kWh
|
$2,880
-
kW-mo/yr
|
- | - | |
| 05 | 2.2511: Insulate bare equipment | $18,874 | $7,590 |
$18,874
1,248,535
kWh
|
- | - | - | |
| 06 | 3.1191: Change procedures / equipment / operating conditions | $1,600 | - | - | - |
$1,600
-
lb
|
- | |
| 07 | 4.652: Replace existing equipment with more suitable substitutes | $37,500 | $2,500 | - | - | - | $37,500 | |
| TOTAL RECOMMENDED | $67,883 | $37,630 |
$23,781
1,369,578
kWh
|
$5,002
-
kW-mo/yr
|
$1,600
-
lb
|
$37,500 | ||
| TOTAL IMPLEMENTED | $19,580 | $8,775 |
$19,251
1,257,034
kWh
|
$329
-
kW-mo/yr
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs