| Assessment Year | 1997 |
|---|---|
| Principal Product | Injection Molding Components |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 72 |
| Plant Area |
35,250
ft2
|
| Annual Production | 1,000,000
lb
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $72,699 | 2,041,325 |
kWh
|
$0.036 |
| Electricity Demand | $51,404 | 2,988 |
kW-mo/yr
|
$17.20 |
| Electricity Fees | $12,725 | - |
|
- |
| Natural Gas | $8,135 | 2,058 |
MMBtu
|
$3.95 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $98,950 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,010 | $1,307 |
$509
17,292
kWh
|
$501
-
kW-mo/yr
|
- | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,671 | $12,962 |
$1,387
46,893
kWh
|
$1,284
-
kW-mo/yr
|
- | - | |
| 03 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $3,775 | $90 |
$3,775
65,651
kWh
|
- | - | - | |
| 04 | 2.4221: Install compressor air intakes in coolest locations | $624 | $600 |
$324
10,844
kWh
|
$300
-
kW-mo/yr
|
- | - | |
| 05 | 4.441: Install automatic packing equipment | $90,870 | $30,000 | - | - |
$6,000
-
lb
|
$84,870 | |
| TOTAL RECOMMENDED | $98,950 | $44,959 |
$5,995
140,680
kWh
|
$2,085
-
kW-mo/yr
|
$6,000
-
lb
|
$84,870 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs