Assessment Year | 1999 |
---|---|
Principal Product | Newspapers |
NAICS |
n/a
|
SIC | 2711: Newspapers: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 170 |
Plant Area |
44,500
ft2
|
Annual Production | 21,500,000
pieces
|
Production Hrs. Annual | 5,824
hrs
|
Location (State) | Alabama |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $81,454 | 2,073,271 |
kWh
|
$0.039 |
Electricity Demand | $26,274 | 5,543 |
kW-mo/yr
|
$4.74 |
Electricity Fees | $33,683 | - |
|
- |
Natural Gas | $4,125 | 314 |
MMBtu
|
$13.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,945 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,555 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8114: Change rate schedules or other changes in utility service | $11,582 | - | - | - | $11,582 | - | - | - | - | - | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,133 | $479 |
$1,957
74,443
kWh
|
- | $1,176 | - | - | - | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,721 | $29,711 |
$6,255
237,397
kWh
|
$1,645
-
kW-mo/yr
|
$3,821 | - | - | - | - | - | - | |
04 | 2.7241: Install outside air damper / economizer on hvac unit | $1,500 | $3,600 |
$937
35,463
kWh
|
- | $563 | - | - | - | - | - | - | |
05 | 3.6124: Burn waste oil for heat | $623 | $1,804 | - | - | - |
$443
-
MMBtu
|
- |
$180
-
gal
|
- | - | - | |
06 | 3.4154: Eliminate leaks in water lines and valves | $3,555 | $250 | - | - | - | - |
$392
-
Tgal
|
- | - |
$497
-
Tgal
|
$2,666 | |
07 | 4.515: Install shelves / racks to utilize unused space | $6,831 | $7,225 | - | - | - | - | - | - | $6,831 | - | - | |
TOTAL RECOMMENDED | $38,945 | $43,069 |
$9,149
347,303
kWh
|
$1,645
-
kW-mo/yr
|
$17,142 |
$443
-
MMBtu
|
$392
-
Tgal
|
$180
-
gal
|
$6,831 |
$497
-
Tgal
|
$2,666 | ||
TOTAL IMPLEMENTED | $3,555 | $250 | - | - | - | - |
$392
-
Tgal
|
- | - |
$497
-
Tgal
|
$2,666 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Administrative Changes Savings | Water Consumption Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs