Assessment Year | 1997 |
---|---|
Principal Product | Industrial Plating |
NAICS |
n/a
|
SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
Sales Range | $5 M to 10M |
# of Employees | 79 |
Plant Area |
63,000
ft2
|
Annual Production | 132,583,100
lb
|
Production Hrs. Annual | 7,344
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $283,752 | 4,235,346 |
kWh
|
$0.067 |
Electricity Demand | $84,183 | 17,604 |
kW-mo/yr
|
$4.78 |
Electricity Fees | $(-5,257.0) | - |
|
- |
Natural Gas | $242,233 | 72,218 |
MMBtu
|
$3.35 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $110,385 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,948 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $171 | $150 |
$156
2,052
kWh
|
$15
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,736 | $8,779 |
$5,188
69,461
kWh
|
$548
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.2511: Insulate bare equipment | $1,162 | $306 | - | - |
$1,162
-
MMBtu
|
- | - | - | |
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,126 | $3,838 | - | - |
$4,126
-
MMBtu
|
- | - | - | |
05 | 3.4111: Use closed cycle process to minimize waste water production | $30,942 | $140,140 | - | - | - |
$30,942
-
Tgal
|
- | - | |
06 | 4.511: Expand operations into unused space | $6,915 | $320 | - | - | - | - | $6,915 | - | |
07 | 3.2161: Closely monitor chemical additions to increase bath life | $61,333 | $480 | - | - | - | - | - | $61,333 | |
TOTAL RECOMMENDED | $110,385 | $154,013 |
$5,344
71,513
kWh
|
$563
-
kW-mo/yr
|
$5,288
-
MMBtu
|
$30,942
-
Tgal
|
$6,915 | $61,333 | ||
TOTAL IMPLEMENTED | $16,948 | $13,087 |
$5,344
71,513
kWh
|
$563
-
kW-mo/yr
|
$4,126
-
MMBtu
|
- | $6,915 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs