| Assessment Year | 1997 |
|---|---|
| Principal Product | Industrial Plating |
| NAICS |
n/a
|
| SIC | 3471: Electroplating, Plating, Polishing, Anodizing, and Coloring |
| Sales Range | $5 M to 10M |
| # of Employees | 79 |
| Plant Area |
63,000
ft2
|
| Annual Production | 132,583,100
lb
|
| Production Hrs. Annual | 7,344
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $283,752 | 4,235,346 |
kWh
|
$0.067 |
| Electricity Demand | $84,183 | 17,604 |
kW-mo/yr
|
$4.78 |
| Electricity Fees | $(-5,257.0) | - |
|
- |
| Natural Gas | $242,233 | 72,218 |
MMBtu
|
$3.35 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $110,385 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $16,948 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $171 | $150 |
$156
2,052
kWh
|
$15
-
kW-mo/yr
|
- | - | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,736 | $8,779 |
$5,188
69,461
kWh
|
$548
-
kW-mo/yr
|
- | - | - | - | |
| 03 | 2.2511: Insulate bare equipment | $1,162 | $306 | - | - |
$1,162
-
MMBtu
|
- | - | - | |
| 04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $4,126 | $3,838 | - | - |
$4,126
-
MMBtu
|
- | - | - | |
| 05 | 3.4111: Use closed cycle process to minimize waste water production | $30,942 | $140,140 | - | - | - |
$30,942
-
Tgal
|
- | - | |
| 06 | 4.511: Expand operations into unused space | $6,915 | $320 | - | - | - | - | $6,915 | - | |
| 07 | 3.2161: Closely monitor chemical additions to increase bath life | $61,333 | $480 | - | - | - | - | - | $61,333 | |
| TOTAL RECOMMENDED | $110,385 | $154,013 |
$5,344
71,513
kWh
|
$563
-
kW-mo/yr
|
$5,288
-
MMBtu
|
$30,942
-
Tgal
|
$6,915 | $61,333 | ||
| TOTAL IMPLEMENTED | $16,948 | $13,087 |
$5,344
71,513
kWh
|
$563
-
kW-mo/yr
|
$4,126
-
MMBtu
|
- | $6,915 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs