| Assessment Year | 1995 |
|---|---|
| Principal Product | Cooper anodes |
| NAICS |
n/a
|
| SIC | 3351: Rolling, Drawing, and Extruding Of Copper |
| Sales Range | $10 M to 50M |
| # of Employees | 45 |
| Plant Area |
77,000
ft2
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $320,113 | 4,142,145 |
kWh
|
$0.077 |
| Natural Gas | $57,917 | 12,049 |
MMBtu
|
$4.81 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $3,099 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $771 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,806 | $4,008 |
$1,806
23,447
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $771 | $2,786 |
$771
9,965
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $286 | $1,200 |
$286
3,810
kWh
|
- | |
| 04 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $236 | $300 | - |
$236
-
MMBtu
|
|
| TOTAL RECOMMENDED | $3,099 | $8,294 |
$2,863
37,222
kWh
|
$236
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $771 | $2,786 |
$771
9,965
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs