| Assessment Year | 1995 |
|---|---|
| Principal Product | Metal heat treating |
| NAICS |
n/a
|
| SIC | 3398: Metal Heat Treating |
| Sales Range | $1 M to 5M |
| # of Employees | 26 |
| Plant Area |
30,000
ft2
|
| Annual Production | 28,000,000
lb
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $107,176 | 1,618,992 |
kWh
|
$0.066 |
| Natural Gas | $201,123 | 57,849 |
MMBtu
|
$3.48 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,489 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,853 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,047 | $760 |
$1,047
15,533
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,609 | $14,020 |
$6,609
97,304
kWh
|
- | |
| 03 | 2.4226: Use / purchase optimum sized compressor | $1,197 | $3,100 |
$1,197
11,723
kWh
|
- | |
| 04 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $4,636 | $1,998 | - |
$4,636
-
MMBtu
|
|
| TOTAL RECOMMENDED | $13,489 | $19,878 |
$8,853
124,560
kWh
|
$4,636
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,853 | $17,880 |
$8,853
124,560
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs