| Assessment Year | 1995 |
|---|---|
| Principal Product | Energy Absorbers for Automotive |
| NAICS |
n/a
|
| SIC | 3714: Motor Vehicle Parts and Accessories |
| Sales Range | $10 M to 50M |
| # of Employees | 185 |
| Plant Area |
105,000
ft2
|
| Annual Production | 9,000,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Michigan |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $343,449 | 4,894,197 |
kWh
|
$0.070 |
| Natural Gas | $125,105 | 23,757 |
MMBtu
|
$5.27 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $28,973 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $1,153 | $1,216 |
$1,153
16,413
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,607 | $28,762 |
$15,607
223,036
kWh
|
- | |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $4,494 | $3,000 |
$4,494
64,185
kWh
|
- | |
| 04 | 2.7224: Reduce space conditioning during non-working hours | $1,581 | - | - |
$1,581
-
MMBtu
|
|
| 05 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $6,138 | $1,500 | - |
$6,138
-
MMBtu
|
|
| TOTAL RECOMMENDED | $28,973 | $34,478 |
$21,254
303,634
kWh
|
$7,719
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs