Assessment Year | 1994 |
---|---|
Principal Product | Stamping dies |
NAICS |
n/a
|
SIC | 3532: Mining Machinery and Equipment, Except Oil and Gas Field Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 100 |
Plant Area |
67,000
ft2
|
Annual Production | 150
pieces
|
Production Hrs. Annual | 5,500
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $175,370 | 2,271,102 |
kWh
|
$0.077 |
Natural Gas | $10,557 | 2,176 |
MMBtu
|
$4.85 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,409 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,769 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $4,756 | $6,500 |
$4,756
61,841
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,040 | $27,295 |
$19,040
247,362
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $780 | $820 |
$780
10,258
kWh
|
- | |
04 | 2.4221: Install compressor air intakes in coolest locations | $1,013 | $800 |
$1,013
13,189
kWh
|
- | |
05 | 2.4226: Use / purchase optimum sized compressor | $2,171 | $5,000 |
$2,171
28,136
kWh
|
- | |
06 | 2.7231: Use radiant heater for spot heating | $2,649 | $6,400 | - |
$2,649
-
MMBtu
|
|
TOTAL RECOMMENDED | $30,409 | $46,815 |
$27,760
360,786
kWh
|
$2,649
-
MMBtu
|
||
TOTAL IMPLEMENTED | $5,769 | $7,300 |
$5,769
75,030
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs