Assessment Year | 1994 |
---|---|
Principal Product | Heat Treatment Services |
NAICS |
n/a
|
SIC | 3398: Metal Heat Treating |
Sales Range | $1 M to 5M |
# of Employees | 65 |
Plant Area |
84,000
ft2
|
Annual Production | 91,892,440
lb
|
Production Hrs. Annual | 7,200
hrs
|
Location (State) | Michigan |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $131,991 | 3,075,909 |
kWh
|
$0.043 |
Natural Gas | $513,636 | 172,322 |
MMBtu
|
$2.98 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $30,361 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,383 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $5,606 | $8,840 |
$5,606
130,422
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,566 | $19,063 |
$4,566
106,096
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $1,408 | $570 |
$1,408
32,825
kWh
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,032 | $3,000 |
$1,032
24,033
kWh
|
- | |
05 | 2.4226: Use / purchase optimum sized compressor | $2,179 | $3,100 |
$2,179
50,703
kWh
|
- | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $15,570 | $6,179 | - |
$15,570
-
MMBtu
|
|
TOTAL RECOMMENDED | $30,361 | $40,752 |
$14,791
344,079
kWh
|
$15,570
-
MMBtu
|
||
TOTAL IMPLEMENTED | $13,383 | $34,003 |
$13,383
311,254
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs